0415 Inner/Outer Diameter Measuring Head
-
Inner Diameter Measuring Heads
-
Outer Diameter Measuring Heads
-
Zero setter for Inner Diameter Measuring Heads
-
Zero setter for Outer Diameter Measuring Heads
Inner Diameter Measuring Heads
Measurement diameters
compatible from
ranges 3 Φ to Φ 100 .
Outer Diameter Measuring Heads
Measurement diameters
compatible from
ranges 15 Φ to Φ 100 .
Zero setter for
Inner Diameter Measuring
Heads
Use for the calibration of the
Inner diameter measuring
head.
Zero setter for
Outer Diameter Measuring
Heads
Use for the calibration of the
Outer diameter measuring
head.
Inner Diameter Measuring Heads
It can measure the Inner diameter of the workpiece.
Measuring Diameter
Measurement diameters compatible from ranges 3 Φ to Φ 100.
Cost performance
Industry’s top class low price products.
Nozzle Position ( mm ) 4 | |||||
---|---|---|---|---|---|
Measuring Diameter Φ D ( mm ) |
Product Code |
Measuring range ( µm ) |
Φ N (mm) |
Outer Appearance/Dimension Diagram | Remarks |
3 ≤ Φ D ≤ 4 | 4701010 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
4 < Φ D ≤ 6 | 4701020 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
6 < Φ D ≤ 8.6 | 4701030 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
4701210 | 40 | 1.5 | A-E: E-DT-AH-310 | ||
8.6 < Φ D ≤ 11.5 | 4701040 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
4701220 | 40 | 1.5 | A-E: E-DT-AH-310 | ||
11.5 < Φ D ≤ 36 | 4701230 | 40 | 1.5 | A-E: E-DT-AH-310 | |
36 < Φ D ≤ 50 | 4701250 | 40 | 1.5 | A-E: E-DT-AH-310 | |
50 < Φ D ≤ 64 | 4701260 | 40 | 1.5 | A-E: E-DT-AH-310 | |
64 < Φ D ≤ 100 | 4701270 | 40 | 1.5 | A-E: E-DT-AH-310 |
Nozzle Position ( mm ) 15 | |||||
---|---|---|---|---|---|
Measuring Diameter Φ D ( mm ) |
Product Code |
Measuring range ( µm ) |
Φ N (mm) |
Outer Appearance/Dimension Diagram | Remarks |
4 < Φ D ≤ 6 | 4701110 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
6 < Φ D ≤ 8.6 | 4701120 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
4701310 | 40 | 1.5 | A-E: E-DT-AH-310 | ||
8.6 < Φ D ≤ 11.5 | 4701130 | 15 | 0.4 | A-E: E-DT-AH-0520 | |
4701320 | 40 | 1.5 | A-E: E-DT-AH-310 | ||
11.5 < Φ D ≤ 36 | 4701330 | 40 | 1.5 | A-E: E-DT-AH-310 | |
36 < Φ D ≤ 50 | 4701350 | 40 | 1.5 | A-E: E-DT-AH-310 | |
50 < Φ D ≤ 64 | 4701360 | 40 | 1.5 | A-E: E-DT-AH-310 | |
64 < Φ D ≤ 100 | 4701370 | 40 | 1.5 | A-E: E-DT-AH-310 |
When placing an order, please specify the following:
- ■ Product Code
- ■ Measuring Diameter
- ■ Tolerance of upper limit level/lower limit level.
* Please consult with us about the nozzle position.
Outer Diameter Measuring Heads
It can measure the Outer diameter of the workpiece.
Measuring Diameter
Measurement diameters compatible from ranges 15 Φ to Φ 100.
Cost performance
Industry’s top class low price products.
Measuring Diameter Φ D ( mm ) |
Product Code | Outer Appearance/Dimension Diagram |
---|---|---|
15 ≤ Φ D ≤ 20 | 4700011 | |
20 < Φ D ≤ 35 | 4700021 | |
35 < Φ D ≤ 50 | 4700031 | |
50 < Φ D ≤ 70 | 4700041 | |
70 < Φ D ≤ 85 | 4700051 | |
85 < Φ D ≤ 100 | 4700061 |
15 ≤ Φ D ≤ 100
Measuring range ( µm ) | A-E |
---|---|
40 | E-DT-AH-311 |
When placing an order, please specify the following:
- ■ Product Code
- ■ Measuring Diameter
- ■ Tolerance of upper limit level/lower limit level.
* Please consult with us about the nozzle position.
Outer Diameter Measuring Heads
It can measure the Outer diameter of the workpiece.
Measuring Diameter
Measurement diameters compatible from ranges 15 Φ to Φ 100.
Cost performance
Industry’s top class low price products.
Measuring Diameter Φ D ( mm ) |
Product Code | Outer Appearance/Dimension Diagram |
---|---|---|
15 ≤ Φ D ≤ 20 | 4700011 | |
20 < Φ D ≤ 35 | 4700021 | |
35 < Φ D ≤ 50 | 4700031 | |
50 < Φ D ≤ 70 | 4700041 | |
70 < Φ D ≤ 85 | 4700051 | |
85 < Φ D ≤ 100 | 4700061 |
15 ≤ Φ D ≤ 100
Measuring range ( µm ) | A-E |
---|---|
40 | E-DT-AH-311 |
When placing an order, please specify the following:
- ■ Product Code
- ■ Measuring Diameter
- ■ Tolerance of upper limit level/lower limit level.
* Please consult with us about the nozzle position.
Zero setter for Inner Diameter Measuring Heads
Use for the calibration of the Inner diameter measuring head.
Zero setter can be used as a simple zero setting jig when the required measuring precision is not so high. However, using Masters (not Zero setters) of periodical precise calibration is needed.
The measured diameter of one axis direction is marked on the top of each zero setter. (The marked value is measured at the depth of 3mm or 5mm from thesurface with marking.) When using the zero setter, the measuring head must be set pointing head’s nozzles to the direction of marked line.
Product Code | Φ D ( mm ) | Φ Do ( mm ) | T ( mm ) |
---|---|---|---|
4702010 | 3 ≤ Φ D ≤ 5 | 30 | 6 |
4702020 | 5 < Φ D ≤ 8 | 30 | 10 |
4702030 | 8 < Φ D ≤ 10 | 34 | 10 |
4702040 | 10 < Φ D ≤ 14 | 34 | 10 |
4702050 | 14 < Φ D ≤ 20 | 42 | 15 |
4702060 | 20 < Φ D ≤ 26 | 50 | 15 |
4702070 | 26 < Φ D ≤ 32 | 58 | 20 |
4702080 | 32 < Φ D ≤ 38 | 64 | 20 |
4702090 | 38 < Φ D ≤ 44 | 74 | 25 |
4702100 | 44 < Φ D ≤ 50 | 84 | 25 |
4702110 | 50 < Φ D ≤ 65 | 104 | 25 |
4702120 | 65 < Φ D ≤ 80 | 124 | 25 |
4702130 | 80 < Φ D ≤ 95 | 144 | 30 |
4702140 | 95 < Φ D ≤ 100 | 164 | 30 |
Zero setter for Outer Diameter Measuring Heads
Use for the calibration of the Outer diameter measuring head.
Zero setter can be used as a simple zero setting jig when the necessary measuring precision is not so high. However, using Masters (not Zero setters) of periodical precise calibration is needed.
The measured diameter of one axis direction is marked on the top of each zero setter. (The marked value is measured around the middle height of zero setter.)
When using the zero setter, the measuring head must be set pointing head’s nozzles to the direction of marked line.
Product Code | Outer Appearance/Dimension Diagram |
---|---|
4702200 | |
4702210 | |
4702220 |
Product Code | Φ D | A | B | C |
---|---|---|---|---|
4702200 | 15 ≤ Φ D ≤ 20 | 12 | – | 10 |
4702210 | 20 < Φ D ≤ 32 | 18 | – | 16 |
32 < Φ D ≤ 45 | 28 | – | 26 | |
45 < Φ D ≤ 50 | 40 | – | 38 | |
50 < Φ D ≤ 60 | 45 | – | 43 | |
4702220 | 60 < Φ D ≤ 70 | 56 | 25 | 54 |
70 < Φ D ≤ 80 | 66 | 30 | 64 | |
80 < Φ D ≤ 90 | 74 | 40 | 72 | |
90 < Φ D ≤ 100 | 84 | 50 | 82 |